AT3600L / AT95E / AT91 can use Technics phono cartridge stand (Screws will only be given when you purchase a record stand + cartridge. If you purchase only one of them separately, they will not be given.)
AT91 parameters
Frequency response: 20-20000Hz
Output voltage: 3.5MV (1khz, 5cm/sec)
Channel separation: 18dB (1khz)
Output balance: 2.5DB (1khz)
Acupuncture pressure: 1.5-2.5g (2.0g standard)
Coil impedance: 2.8kΩ (1khz)
DC resistance: 410Ω
Recommended load impedance: 47kΩ
Recommended load capacitance: 100-200pF
Coil inductance: 400mH (1khz)
Static compliance: 200x10-6 cm/dyne
Dynamic compliance: 6.5x10-6 cm/dyne (100hz)
Stylus: Jointed tapered tip
Stylus tip curvature radius: 0.6mil
Needle arm: carbon fiber rod
Vertical tracking angle: 20°
Size: 17.0*16.8*31.0mm (height*width*depth)
M-type dual moving magnet stereo cartridge
AT-VM95C
VM95 Series 0.3 x 0.7 mil Bonded Oval Pin Cartridges
Compatible and upgradeable to its stylus assembly
A classic style that is widely loved by vinyl fans around the world, with a new design that can be replayed with a variety of needle tips
Patented VM type double moving magnetic design
Rugged, low resonance polymer chassis
Sturdy aluminum alloy tubular needle bar
Specially designed internal thread on the body, only two screws are needed to install on the phono cover, no nut is required
VM cassette with improved output voltage, dynamic range, frequency characteristics, etc. 4.0mV high output power. Aluminum tube cantilever. High rigidity resin case. With the embedded nut structure, it is easy to install on the housing-integrated tone arm. The needle is easy to fall on the target position, and the design of the high visibility of the needle tip. Needle replacement list "With the needle tip compatibility of the AT-VM95 series, it is possible to change to a desired needle" >>>
AT-VM95C Specifications
AT-VM95C Specifications
category
VM type moving magnet cartridge
Broadcast frequency range
20 ~ 20,000Hz
The output voltage
4.0 mV (1kHz at 5cm per second)
channel separation
18dB (1kHz)
channel error
2.5dB (1kHz)
Acupuncture
1.8 - 2.2 g (2.0 g standard)
Coil impedance
3,300 ohms (1kHz)
DC resistance
485 ohms
load impedance
47,000 ohms
load capacity
100 ~ 200pF
Coil Inductance
550 mH (1kHz)
static softness
17 x 10-6cm/dyne
dynamic compliance
6.5 x 10-6cm/dyne (100Hz)
stylus tip shape
0.6 mil mating round needle
Original Audio-Technica 3600L vinyl record player MM cartridge diamond stylus suitable for LP60 310BT
The stylus is a worn-out product, and its normal service life is about 300-400 hours. Except for damage caused by careless operation, the use of excessive needle pressure, shoddy inferior records and severely shaking turntables will shorten the life of the needle tip. As the radius of curvature of the sharpened needle tip becomes larger, its ability to track high-frequency signals in the acoustic groove decreases. When the sound details are reduced, the treble is gradually poor, and the sound becomes more and more dull, you need to consider replacing the cartridge. Currently on the market Most vinyl record players above use MM cartridges. The Audio-Technica cartridge is basically universal, just confirm whether it can be fixed to the tonearm stand. Cartridge fixed hole distance: 13mm (measure the center distance between the two holes)
The phono terminal has 4 pin wiring indications of R+, R-, L+, L- (see Figure 2 below)
The general color of the phono terminal wiring is: R+=red, R-=green, L+=white, L-=blue
Suggested acupuncture pressure range: 1.5g-2g, adjust the acupuncture pressure according to personal listening preferences。
Audio Technica AT95E Moving Magnet Stereo Cartridge Stylus For LP Vinyl Record Player Turntable Phonograph Hi-Fi Accessories
The AT95E cartridge provides excellent resolution and detail. High performance cartridge. Audio-Technica has high quality standards, each cartridge is carefully manufactured, and errors are strictly controlled. The oval diamond can reproduce the music with high precision. Mounting accessories are included in the box.
Phono fixed hole distance: 10mm (measurement center distance is 12.5mm) distribution fixed rose
Phono category: MM moving magnet
Response frequency: 20~20,000Hz
Output voltage: 3.5mV (1kHz, 5cm/sec.)
Channel separation: 20dB (1kHz)
Output Balance: 2.0dB (1kHz)
Acupuncture pressure: 1.5-2.5g (recommended gauge pressure 2.0g)
Coil Impedance: 2.8kΩ (1kHz)
Coil DC resistance: 410Ω
Recommended load resistance: 47kΩ
Load capacitance: 100~200pF
Coil Inductance: 400mH (1kHz)
Static compliance: 20×10-6cm/dyne
Dynamic compliance: 6.5×10-6cm/dyne(100Hz)
Tip Shape: Engaged oval needle (0.4×0.7mil)
Needle bar: aluminum alloy tubular
Vertical tracking angle: 20°
Dimensions: H17.2×W17.0×D30.5mm
Cartridge weight: 5.7g