Katalog
5 Fotoğraf
4 Yorumlar
4
A
ar********on
12 Oct 2024
jm*hr - 1
jm*hr
06 Oct 2024
lo******an - 2
lo******an
01 Oct 2024
gr*********ie - 3
gr*********ie
07 Oct 2024
Özellikler
Size
48*96*80mm
Type
Floor Scale
Input
1-4 loadcells
Origin
Mainland China
Output
2 relay
Display
4 digit
Accuracy
0.1%F.S±2digit
Brand Name
MPDQ(电子)
Display Type
LED
Model Number
LM8-RND
Power supply
110V/220V AC
Products Name
Loadcell indicator
Is Smart Device
no
Daha fazlasını gör
Tanım

MYPIN

MYPIN ELECTRICAL CO.,LTD

Add:No7,Lane 5,Str Anhe,Fengyu road ,Zhongshan ,Guangdong ,China

Whatsapp/wechat:18676133547

Products description

1.Products display

Title 1, mypin(LM8-RR4D)loadcell indicator ,weighing con...Title 2, mypin(LM8-RR4D)loadcell indicator ,weighing con...



2.Technical specification

Model:LM8-RR4D

Mypin LM series 4 LED digital display Loadcells indicator

  • Input:1-4 loadcells

  • Output:2 relay

  • Comonmunication :RS485

  • Size :48*96*80mm

  • Accuracy :0.1%F.S±2digit

  • Sampling speed:≤16times/sec
  • Weight:0.35KgTitle 3, mypin(LM8-RR4D)loadcell indicator ,weighing con...


3.Operation/Parameter setting

  • press and hold SETkey until to enter setting menu.
  • Press<< /Rst key once, LED flashing
  • Press << /Rst to shift LED if need
  • Press Up or Down key to modify data,
  • Press SET key to confirm data.
  • Press SET key to read other parameters, and repeat B,C,D steps to modify data if need
  • Press and hold SET key until to quit menu

Title 4, mypin(LM8-RR4D)loadcell indicator ,weighing con...

4.Weight Adjustment:

  • When empty (no load),press DOWN key until ‘Oy’ flashing. release DOWN key ; PV LED displays about 0
  • Follow step 1,placing the weight of this calibration, press UP key until SV LED flashing.
  • Release UP key.refer parameter setting step to set SV LED data,SV LED data = the weight of this calibration (Equal USP parameter),
  • E.g,the calibrate weight is 50Kg, Setting SV data=50.00, the unit is Kg, Setting SV data=0.050, the unit is Ton
  • Refer Page 2(Manual)to lock adjust operation If need

5.Clear tare weight :

press << / Rst key until ‘oy’ flashs to clear tare or short external RST terminal once to clear tare
 
6.The instrument will auto-return to the measuring estate without any operation for 25 seconds
 
Note: Zero display (option,refer page 2)
when empty or no load
if need PV window display 0 when no load, then set PF2 >= |PV| ,
  • E.g when no load,PV display range: -0.2--+0.2, set PF2=0.3 > |PV|=0.2, PV will display 0.0,
  • But if PV > PF2, E.g PV value =0.31> 0.2, PV LED will normal display 0.31.

7.Series Introduction

  • 1 Weight measurement and control *Mixed Batching control
  • Direct Load :1-4 PCS loadcells, 24 Bits A / D
  • Digital Input: Start / Stop and Clear Tare
  • Output::4-20mA / 0-10V , Relay / SSR / Logic output
  • Data Peak value holding function for choice.
  • Communication : RS485 RS232,RJ45(LAN) MODBUS-RTU protocol.
  •  
    Title 5, mypin(LM8-RR4D)loadcell indicator ,weighing con...

*(The above description is the full range of functions included in the TA series.

If required, please select the appropriate model to prevent the function from being unavailable.)

Daha fazlasını gör
74.4$
4
4 yorumlar 15 satıldı

mypin(LM8-RR4D)loadcell indicator ,weighing controller, LED Weight Controller 1-4 Load Cell Signals Input 2 Relay Output

Teslimat düzenlemek Brazil

Color: LM8-RR4D

LM8-RR4D
1
Stokta var: 100
Şimdi sipariş ver
Sepete ekle
Yayınlanan: 15.04.2024 16:28 Stokta var: 100 548Görüntüleme

Aynı kategorideki reklamlar